Formed in October 1991, ECOM Ltd is a Czech company located in Prague. ECOM Ltd is a world known quality supplier of equipments for liquid chromatography, first of detectors for flash, preparative and analytical purposes, just now of complete systems for analytical and preparative HPLC.
ECOM HPLC Systems integrating advance modular LC Components with ECOM ECOMAC or DataApex Clarity Chromatography Software.
Analytical HPLC System Sets
ECS01 Quaternary gradient analytical system
For complicated analysis at different wavelengths in gradient mode
Cat. ASA0100X
ECS01 SYSTEM CONTAINS | ||
P/N | Description | Quantity (Pcs) |
ADA0000X | ECD2800 UV-VIS Detector with Deuterium Lamp and Halogen Lamp (190-800nm) | 1 |
ABA0000X | ECB2004 Gradient Box with Degasser | 1 |
ACA0000X | ECP2010 Analytical HPLC Pump | 1 |
AOA0000X | ECO2080 Column Oven with Heating and Cooling | 1 |
AP000C50 | Clarity — Station for 1 Instrument | 1 |
AP000A24 | Clarity Module for HPLC Control | 1 |
S203200X | Ana. Injection Valve with 20ul Sample | 1 |
ASA00180 | Accessories for analy. System Series 2000 | 1 |
ECS02 Quaternary gradient analytical system
For complicated analysis at different wavelengths in gradient mode (up to 600nm)
Cat. ASA0200X
ECS02 SYSTEM CONTAINS | ||
P/N | Description | Quantity (Pcs) |
ADB0000X | ECD2600 UV-VIS Detector with Deuteurim Lamp (190-600nm) | 1 |
ABA0000X | ECB2004 Gradient Box with Degasser | 1 |
ACA0000X | ECP2010 Analytical HPLC Pump | 1 |
AOB0000X | ECO2099 Column Oven with Heating | 1 |
AP000C50 | Clarity — Station for 1 Instrument | 1 |
AP000A24 | Clarity Module for HPLC Control | 1 |
S203200X | Ana. Injection Valve with 20ul Sample Loop | 1 |
ASA00180 | Accessories for analy. System Series 2000 | 1 |
ECS03 Isocratic analytical system
For complicated analysis at different wavelengths in isocratic mode (up to 600nm)
Cat. ASA0300X
ECS03 SYSTEM CONTAINS | ||
P/N | Description | Quantity (Pcs) |
ADB0000X | ECD2600 UV-VIS Detector with Deuteurim Lamp (190-600nm) | 1 |
ABC0000X | ECB2006 Box for Mobile Phase Bottles | 1 |
ACA0000X | ECP2010 Analytical HPLC Pump | 1 |
AP000C50 | Clarity — Station for 1 Instrument | 1 |
AP000A24 | Clarity Module for HPLC Control | 1 |
S203200X | Ana. Injection Valve with 20ul Sample Loop | 1 |
ASA00180 | Accessories for analytical. System Series 2000 | 1 |
ECS04 Quaternary gradient analytical system with autosampler
For complicated analysis at different wavelengths (up to 800nm) in gradient mode
Cat. ASA0400X
ECS04 SYSTEM CONTAINS | ||
P/N | Description | Quantity (Pcs) |
ADA0000X | ECD2800 UV-VIS Detector with Deuterium Lamp and Halogen Lamp (190-800nm) | 1 |
ABA0000X | ECB2004 Gradient Box with Degasser | 1 |
ACA0000X | ECP2010 Analytical HPLC Pump | 1 |
AOA0000X | ECO2080 Column Oven with Heating and Cooling | 1 |
ARA03320 | Autosampler L3320 for 2×48 vials | 1 |
AP000C50 | Clarity — Station for 1 Instrument | 1 |
AP000A24 | Clarity Module for HPLC Control | 1 |
AP000A26 | Clarity SW Module for AS Control | 1 |
ASA00180 | Accessories for analy. System Series 2000 | 1 |
ECS05 Quaternary gradient analytical system with PDA detector with autosampler
For complicated analysis at different wavelengths (up to 800nm) in gradient mode
Cat. ASA0500X
ECS05 SYSTEM CONTAINS | ||
P/N | Description | Quantity (Pcs) |
ANW0000X | ECD2800 UV-VIS PDA Detector with Deuterium Lamp and Halogen Lamp (190-800nm) | 1 |
ABA0000X | ECB2004 Gradient Box with Degasser | 1 |
ACA0000X | ECP2010 Analytical HPLC Pump | 1 |
AOA0000X | ECO2080 Column Oven with Heating and Cooling | 1 |
ARA03320 | Autosampler L3320 for 2×48 vials | 1 |
AP000C50 | Clarity — Station for 1 Instrument | 1 |
AP000A24 | Clarity Module for HPLC Control | 1 |
AP000A26 | Clarity SW Module for AS Control | 1 |
ASA00180 | Accessories for analy. System Series 2000 | 1 |
Flash chromatography and preparative HPLC system sets
ECS10 Quaternary Gradient Preparative System
Cat. ASP1000X
ECS 10 SYSTEM CONTAINS | ||
P/N | Description | Quantity (Pcs) |
ANB0000X | Flash 14 DAD 600 Detector | 1 |
ABD0000X | ECB2007 Gradient Box without Degasser | 1 |
ACD0000X | ECP2100 Preparative Pump | 1 |
AF000000 | ECOMAC Software | 1 |
S203200X | Analytical Injection Valve with 20ul Sample Loop | 1 |
SY2124009 | Sample Loop SS 1ml 1/16” | 1 |
ASP00180 | Accessories for Prep. System Series 2000 | 1 |
ECS11 Isocratic Preparative system
Cat. ASP1100X
ECS 11 SYSTEM CONTAINS | ||
P/N | Description | Quantity (Pcs) |
ANA0000X | Flash 14 DAD 400 Detector | 1 |
ABC0000X | ECB2006 Box for Mobile Phase Bottles | 1 |
ACD0000X | ECP2100 Preparative Pump | 1 |
AF000000 | ECOMAC Software | 1 |
S203200X | Analytical Injection Valve with 20ul Sample Loop | 1 |
SY2124009 | Sample Loop SS 1ml 1/16” | 1 |
ASP00180 | Accessories for Prep. System Series 2000 | 1 |
ECS12 Quaternary Gradient Preparative System with Fraction Collector
Cat. ASP1200X
ECS 12 SYSTEM CONTAINS | ||
P/N | Description | Quantity (Pcs) |
ANB0000X | Flash 14 DAD 600 Detector | 1 |
ABB0000X | ECB2005 Gradient Box without Degasser | 1 |
ACE0000X | ECP2300 Preparative Pump | 1 |
AF000000 | ECOMAC Software | 1 |
AFA00000 | ECF2096 Fraction Collector | 1 |
S2032022 | Preparative Injection Valve 1/8”; 2mL loop | 1 |
AP00MC01 | MultiCom 1xUSB to 6x RS232 Converter | 1 |
ASP00180 | Accessories for Prep. System Series 2000 | 1 |
Isocratic and gradient HPLC pumps up to 10ml/min for analytical practice in HPLC
ECP2010H Analytical HPLC Pump
0,01-10,00 ml/min isocratic/gradient pistons connected in series, pressure up to 60 MPa.
2010H Pump Technical Parameters | |
Flow rate | 0.01 – 10.00 ml/min. |
Pumping system | two plungers dia. 1/8″ connected in Series |
Max. operating pressure | 60 Mpa (8700 psi, 600 bar) |
Accuracy of flow rate (1 ml/min, 12MPa, H20) | +/- 2% |
Repeatability of flow rate | +/- 0.5% |
Accuracy of pressure measurement | +/- 2% |
Adjustable lower pressure limit | 0.0 – 59.0 Mpa |
Adjustable upper pressure limit | 1.0 – 60.0 Mpa |
Number of Valves* | 4 (A, B, C, D) |
Setting of components concentrations* | 0.0 – 100,0% |
Wetted materials | stainless steel, sapphire, KEL-F, seals** |
Communication | RS232, Ethernet (LAN), USB |
Display, keypad | VFD 140×32 pixel, 10 pushbuttons |
Power supply | 100-240V, 50/60Hz, 100VA |
Dimensions (w x h x d) | 280 x 135 x 498 mm |
Weight | 10 kg |
* gradient functions are available only with Gradient Box | |
with Degasser ECB2004 | |
** seals material: default is GFP (PTFE), | |
option is UHMW-PE, more information on request |
ECP2010 analytical HPLC pump
0,01-10,00 ml/min isocratic/gradient pistons connected in series, pressure up to 40 MPa.
Cat. ACA0000X
2010 Pump Technical Parameters | |
Flow rate | 0.01 – 10.00 ml/min. |
Pumping system | two plungers dia. 1/8″ connected in Series |
Max. operating pressure | 40 Mpa (5800 psi, 400 bar) |
Accuracy of flow rate (1 ml/min, 12MPa, H20) | +/- 2% |
Repeatability of flow rate | +/- 0.5% |
Accuracy of pressure measurement | +/- 2% |
Adjustable lower pressure limit | 0.0 – 39.0 Mpa |
Adjustable upper pressure limit | 1.0 – 40.0 Mpa |
Number of Valves* | 4 (A, B, C, D) |
Setting of components concentrations* | 0.0 – 100,0% |
Wetted materials | stainless steel, sapphire, KEL-F, seals** |
Communication | RS232, Ethernet (LAN), USB |
Display, keypad | VFD 140×32 pixel, 10 pushbuttons |
Power supply | 100-240V, 50/60Hz, 100VA |
Dimensions (w x h x d) | 280 x 135 x 498 mm |
Weight | 10 kg |
* gradient functions are available only with Gradient Box | |
with Degasser ECB2004 | |
** seals material: default is GFP (PTFE), | |
option is UHMW-PE, more information on request |
Gradient boxes, boxes with degasser, boxes for mobile phase reservoirs and accessories for these units.
ECB2004 Gradient Box with Degasser
On-line degassing of solvents up to 10 ml/min and four-way gradient
Cat. ABA0000X
ECB2004 Technical Parameters | |
Degasser channels | 5 independent |
Degassing process | Gas permeation through a fluoropolymer membrane |
Maximal flow rate | 10 mL/min |
Degassing capacity | ̴ 2 ppm at 1 mL/min |
Dead volume | ̴ 480 µl per channel |
Wetted materials | PEEK, Glass-filled PTFE, Teflon AF® |
Gradient Valve | |
Number of gradient valves | 4 (A, B, C, D) |
Max. operating pressure | 1.38 bar (20 psi) |
Orifice | 0.062” (1.6 mm) |
Wetted materials | PTFE |
Common parameters | |
Connecting thread | 1/ 4”-28 flat bottom |
Power supply | 100-240V, 50/60Hz, 20VA |
Inside box dimensions (w x h x d) | 267 x 56 305 mm (10.5” x 2.2” x 12”) |
Dimensions (w x h x d) | 280 x 135 x 498 mm (11” x 5.3” x 18.9”) |
Weight | 7 kg (15.4 ib) |
ECB2005 Preparative gradient box without degasser
Four-way gradient valve and reservoir for mobile phase reservoirs.
Cat. ABB0000X
ECB2005 Technical Parameters | |
Gradient Valve | |
Number of gradient valves | 4 (A, B, C, D) |
Max. operating pressure | 1.38 bar (20 psi) |
Orifice | 0.125” (3.175 mm) |
Wetted materials | PTFE |
Common parameters | |
Connecting thread | 1/ 4”-28 flat bottom |
Power supply | Powered from the pump |
Inside box dimensions (w x h x d) | 267 x 56 305 mm (10.5” x 2.2” x 12”) |
Dimensions (w x h x d) | 280 x 135 x 498 mm (11” x 5.3” x 18.9”) |
Weight | 5 kg (11 lb) |
ECB2006 Box for Mobile Phase Bottles
Box for solvent bottles.
Cat. ABC0000X
ECB2006 Technical Parameters | |
Inside box dimensions (w x h x d) | 270 x 56 x 442 mm (10.5” x 2.2” x 17.42”) |
Dimensions (w x h x d) | 280 x 135 x 498 mm (11” x 5.3” x 18.9”) |
Weight | 2 kg (4.4 ib) |
ECB2007 Gradient Box without Degasser
Box for handling liquids with four-way gradient valve.
Cat. ABD0000X
ECB2007 Technical Parameters | |
Gradient Valve | |
Number of gradient valves | 4 (A, B, C, D) |
Max. operating pressure | 1.38 bar (20 psi) |
Orifice | 0.060” (1.52 mm) |
Wetted materials | PTFE |
Common parameters | |
Connecting thread | 1/ 4”-28 flat bottom |
Power supply | 100-240V 50/60Hz 20VA |
Inside box dimensions (w x h x d) | 267 x 56 305 mm (10.5” x 2.2” x 12”) |
Dimensions (w x h x d) | 280 x 135 x 498 mm (11” x 5.3” x 18.9”) |
Weight | 7 kg (15.4 lb) |
ECB2008 Box with Degasser
Continuous degassing of mobile phase and
container for solvent bottles.
Cat. ABE0000X
UV-VIS HPLC detectors
The ECOM Company offers wide range of detectors suitable for analytical, preparative HPLC and FLASH chromatography applications. Large number of flow-cells with flow-rates from micro liters to liters per minute allows wide use of the detectors.
ECD detectors series are designed for sophisticated analytical applications. Flash series are mostly targeted to flash and preparative applications.
STAND-ALONE UNITS IN CASE POWERED BY 90-264 V AC
Name | Range [nm] | Detector Type | Scan | Notes |
Series 2000 |
variable wavelength, high-speed sampling 100Hz |
|||
ECD2800 | 190-800 | 1x Variable | No | Analytical |
ECD2600 | 190-600 | 1xVariable | No | Analytical |
ECDA2000 series |
Photo Diode Detector PDA (DAD), with display and keyboard |
|||
ECDA2800 UV-VIS PDA Detector | 200-800 | 8x variable | Yes | Analytical.Clarity 3D evaluation |
Flash 14 DAD series |
Diode array – DAD (PDA), without display and keypad |
|||
Flash 14 DAD 400 | 200-400 | 4xVariable | Full | Preparative, Clarity 3D evaluation |
Flash 14 DAD 600 | 200-600 | 4xVariable | Info | Preparative, info scan |
Flash 14 DAD 800 | 190-840 | 4xVariable | Full | Preparative, Clarity 3D evaluation |
ECD2600 Analytical UV-VIS Detector
Programmable wavelength adjusting 190 up to 600nm
Cat. ADB0000X
ECD2600 Detector Technical Parameters | |
Wavelength range | 190-600 nm |
Spectral half-width | 6 nm |
Accuracy of adjustment | +/- 1 nm |
Reproducibility | +/- 0.5nm |
Light source | Deuterium discharge lamp |
Noise (Test cell, 254 nm TC 1 s, 10Hz) | +/- 3.10-6 AU |
Drift (Test cell, 254 nm) | 1.10-4 AU/hr. |
Time Constant | 20-10,000ms |
Sampling rate | up to 100 Hz |
Digital output | 1 V/AU |
Analog output | 1 x configurable |
Wetted materials | depend on a cell- PTFE, fused silica, stainlesssteel, Vespel, PEEK |
Communication | RS232, Ethernet (LAN) |
Display, keypad | VFD 140×32 pixels, 10 pushbuttons |
Power supply | 100-240V, 50/60Hz, 110VA |
Dimensions (w x h x d) | 280 x 135 x 498 mm |
Weight | 9 kg |
ECD2800 Analytical UV-VIS Detector
Programmable wavelength adjusting 190 up to 800nm
Cat. ADA0000X
ECD2800 Detector Technical Parameters | |
Wavelength range | 190-800 nm |
Spectral half-width | 6 nm |
Accuracy of adjustment | +/- 1 nm |
Reproducibility | +/- 0.5nm |
Light source | Deuterium discharge lamp Halogen Lamps |
Noise (Test cell, 254 nm TC 1 s, 10Hz) | +/- 3.10-6 AU |
Drift (Test cell, 254 nm) | 1.10-4 AU/hr. |
Time Constant | 20-10,000ms |
Sampling rate | up to 100 Hz |
Digital output | 1 V/AU |
Analog output | 1 x configurable |
Wetted materials | depend on a cell- PTFE, fused silica, stainlesssteel, Vespel, PEEK |
Communication | RS232, Ethernet (LAN) |
Display, keypad | VFD 140×32 pixels, 10 pushbuttons |
Power supply | 100-240V, 50/60Hz, 110VA |
Dimensions (w x h x d) | 280 x 135 x 498 mm |
Weight | 9 kg |
ECDA2800 UV-VIS PDA detector
Analytical DAD (PDA) detector, variable wavelength 200 up to 800nm,
High-speed sampling 100Hz
Cat. ANW0000X
ECDA2800 Detector Technical Parameters | |
Wavelength range | 190-800 nm |
Spectral half-width | 10 nm |
Number of CCD elements | 512, mathematically enhanced to 4096 by sophisticated algorithm |
Accuracy of adjustment | ‘+/- 1 nm |
Reproducibility | ‘+/- 0.5 nm |
Light source | Deuterium discharge lamp, Halogen Lamps |
Noise (Test cell, 254 nm TC 1 s, 10Hz) | +/- 5.10-6 AU |
Drift (Test cell, 254 nm) | 1.10-4 AU/hr. |
Time Constant | 20-10,000ms |
Sampling rate | up to 100 Hz |
Digital output | 1 V/AU |
Analog output | 4 x configurable |
Wetted materials | fused silica, stainless steel,PEEK |
Communication | RS232, Ethernet (LAN), USB |
Display, keypad | VFD 140×32 pixels, 10 pushbuttons |
Power supply | 100-240V, 50/60Hz, 110VA |
Dimensions (w x h x d) | 280 x 135 x 498 mm (11.0” x 5.3” x 19.6”) |
Weight | 9 kg |
Flash 14 DAD 400 Detector
Four wavelengths simultaneously, continual scan with 5Hz speed,
Clarity PDA module support for 3D measuring
Cat. ANA0000X
Flash 14 DAD 400 Detector Technical Parameters | |
Wavelength range (four wavelengths simultaneously) | 200 – 400 nm (256 elements on CCD |
Scan | 200 – 400 nm, 5 Hz, Step 1 nm |
Typical Spectral half-width | 8 nm |
Accuracy of adjustment | +/- 1 nm |
Reproducibility | +/- 0.5 nm |
Light source | Deuterium discharge lamp |
Noise (Test cell, 254 nm TC 0.75 s,) | +/- 5.10-5 AU |
Drift (Test cell, 254 nm after 1 hr) | 1.10-3 AU/hr. |
Materials in Contact with mobile phase | PTFE; fused silica; stainless steel |
Time Constant (T90) | 0.5s; 0.75s; 1s or 2s
(T63 0.3 s; 0.4s; 0.6 s, 1 s) |
Output for Integrator | 1 V/AU in digital form only |
Interface | RS232 |
Power supply | 90-264 V |
Power input | 90VA |
Dimensions (w x h x d) | 280 x 130 x 463 mm (11.0” x 5.1” x 18.2”) |
Weight | 9 kg (19.8 lb)9 kg |
Preparative cell PLCC 15 (supplied with unit, in special holder): | |
Volume /optical path (adjustable) | 45 µl/0.3 mm; 55 µl/1.4 mm;
70 µl/2.4 mm |
Cell connection | Tubing with OD 1/8”, thread 1/ 4”-28 |
Maximal flow rate | 500 ml/min. |
Flash 14 DAD 600 Detector
Four wavelengths simultaneously, actual spectra visualization
Cat. ANB0000X
Flash 14 DAD 600 Detector Technical Parameters | |
Wavelength range (four wavelengths simultaneously) | 200 – 600 nm |
Typical Spectral half-width | 8 nm |
Number of CCD elements | 256 elements on CCD |
Accuracy of adjustment | +/- 1 nm |
Reproducibility | +/- 0.5 nm |
Light source | Deuterium discharge lamp |
Noise (Test cell, 254 nm TC 0.75 s,) | +/- 5.10-5 AU |
Drift (Test cell, 254 nm after 1 hr) | 1.10-3 AU/hr. |
Materials in Contact with mobile phase | PTFE; fused silica; stainless steel |
Time Constant (T90) | 0.5s; 0.75s; 1s or 2s
(T63 0.3 s; 0.4s; 0.6 s, 1 s) |
Output for Integrator | 1 V/AU in digital form only |
Interface | RS232 |
Power supply | 90-264 V |
Power input | 90VA |
Dimensions (w x h x d) | 280 x 130 x 463 mm (11.0” x 5.1” x 18.2”) |
Weight | 9 kg (19.8 lb) |
Preparative cell PLCC 15 (supplied with unit, in special holder): | |
Volume /optical path (adjustable) | 45 µl/0.3 mm; 55 µl/1.4 mm;
70 µl/2.4 mm |
Cell connection | Tubing with OD 1/8”, thread 1/ 4”-28 |
Maximal flow rate | 500 ml/min. |
Flash 14 DAD 800 Detector
Four wavelengths simultaneously, continual scan with 5Hz speed,
Clarity PDA module support for 3D measuring
Cat. ANC0000X
Flash 14 DAD 800 Detector Technical Parameters | |
Wavelength range (four wavelengths simultaneously) | 200 – 800 nm (256 elements on CCD |
Scan | 200 – 800 nm, 5 Hz, Step 3 nm |
Typical Spectral half-width | 10 nm |
Accuracy of adjustment | +/- 1 nm |
Reproducibility | +/- 0.5 nm |
Light source | Deuterium discharge lamp and halogen lamp |
Noise (Test cell, 254 nm TC 0.75 s,) | +/- 5.10-5 AU |
Drift (Test cell, 254 nm after 1 hr) | 1.10-3 AU/hr. |
Materials in Contact with mobile phase | PTFE; fused silica; stainless steel |
Time Constant (T90) | 0.5s; 0.75s; 1s or 2s
(T63 0.3 s; 0.4s; 0.6 s, 1 s) |
Output for Integrator | 1 V/AU (in digital form only) |
Interface | RS232 |
Power supply | 90-264 V |
Power input | 90VA |
Dimensions (w x h x d) | 280 x 130 x 463 mm (11.0” x 5.1” x 18.2”) |
Weight | 9 kg (19.8 lb) |
Preparative cell PLCC 15 (supplied with unit, in special holder): | |
Volume /optical path (adjustable) | 45 µl/0.3 mm; 55 µl/1.4 mm;
70 µl/2.4 mm |
Cell connection | Tubing with OD 1/8”, thread 1/ 4”-28 |
Maximal flow rate | 500 ml/min. |
Detectors for capillary electrophoresis
ECOM designed ECD2800 and ECD2600 UV-VIS Variable Wavelength Detector version, suited for CE (Capillary electrophoresis).
Cell for quartz capillaries implementation is located at detector front panel.
Cat. ADBEX00X
ECD2600 CE for Capillary Electrophoresis
Programmable wavelength adjusting 190 up to 600nm, application for capillary electrophoresis.
Cat. ADACE00X
ECD2800 CE for Capillary Electrophoresis
Programmable wavelength adjusting 190 up to 800nm, application for capillary electrophoresis.
Software and Hardware for chromatography PC stations
Software and Hardware for control and data acquisition on chromatographic systems (HPLC,Flash). Software for data handling and evaluation.
- Software for controlling devices and for chromatographic data acquisition and evaluation.
- Analog to digital converters (A/D converters).
- Logical input/output units.
- Cables and RS232-USB converters.
Hardware ECOMAC Software Clarity(DataApex)
Spare parts
Common spare parts for HPLC devices like detector lamps, pump seals, flowcell parts etc.
Lamps Seals Check Valves Cells parts